language Türkçe
Review 2023 · 27 citations

Personal glucose meters coupled with signal amplification technologies for quantitative detection of non-glucose targets: Recent progress and challenges in food safety hazards analysis

He, Feng, Wang, Haijie, Du, Pengfei, Li, Tengfei, Wang, Weiting, Tan, Tianyu, Liu, Yaobo, Ma, Yanli, Wang, Yuanshang, Abd El-Aty, A. M.

Abstract

Ensuring food safety is paramount worldwide. Developing effective detection methods to ensure food safety can be challenging owing to trace hazards, long detection time, and resource-poor sites, in addition to the matrix effects of food. Personal glucose meter (PGM), a classic point-of-care testing device, possesses unique application advantages, demonstrating promise in food safety. Currently, many studies have used PGM-based biosensors and signal amplification technologies to achieve sensitive and specific detection of food hazards. Signal amplification technologies have the potential to greatly improve the analytical performance and integration of PGMs with biosensors, which is crucial for solving the challenges associated with the use of PGMs for food safety analysis. This review introduces the basic detection principle of a PGM-based sensing strategy, which consists of three key factors: target recognition, signal transduction, and signal output. Representative studies of existing PGM-based sensing strategies combined with various signal amplification technologies (nanomaterial-loaded multienzyme labeling, nucleic acid reaction, DNAzyme catalysis, responsive nanomaterial encapsulation, and others) in the field of food safety detection are reviewed. Future perspectives and potential opportunities and challenges associated with PGMs in the field of food safety are discussed. Despite the need for complex sample preparation and the lack of standardization in the field, using PGMs in combination with signal amplification technology shows promise as a rapid and cost-effective method for food safety hazard analysis. (c) 2023 The Author(s). Published by Elsevier B.V. on behalf of Xi'an Jiaotong University. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).

Keywords
Food safety Personal glucose meter Signal amplification Point -of -care testing Detection principle GLUCOMETER READOUT GOLD NANOPARTICLES BLOOD-GLUCOSE COLI O157H7 ISOTHERMAL AMPLIFICATION LIQUID-CHROMATOGRAPHY SENSITIVE DETECTION CIRCULAR-DICHROISM MASS SPECTROMETRY DNA
WoS Categories
Pharmacology & Pharmacy
Sustainable Development Goals
Citation
Journal
JOURNAL OF PHARMACEUTICAL ANALYSIS
Year
2023
Volume
13
Issue
3
Pages
223-238
ISSN
2095-1779
eISSN
2214-0883
DOI
10.1016/j.jpha.2023.02.005
WoS UID
WOS:000975856800001
Open via DOI