Atatürk Üniversitesi Atatürk Üniversitesi
Ara
Yayınlara dön
Makale Tam Makale Uluslararası 2025

A new lab-made screen-printed electrode system based on reduced graphene oxide-subphthalocyanine functionalized with ferrocene for electrochemical detection of acetaminophen

Haala Alahmad, Elif Yıldız Gül, Burcu Topaloğlu Aksoy, Fatih Biryan, Kenan Koran, Esra Tanrıverdi Eçik, Salih Zeki Bas, Keziban Atacan, Mustafa Ersoz, Mustafa Ozmen, Bünyemin Çoşut

Microchemical Journal Cilt 208 · 01.01.2025
DOI ile aç

Özet

Acetaminophen (Ac) is a pharmaceutically active ingredient widely used in the treatment of pain and fever. However, an acute oral overdose of more than 12 g of Ac is considered a toxic dose and poses a high risk of liver damage. This study presents the development of a new laboratory-made screen-printed electrode modified with reduced graphene oxide (rGO)-subphthalocyanine-functionalized with ferrocene (SubPc-Fc) to detect Ac. Initially, subphthalocyanine (SubPc) was synthesized using a known method from the literature and was then functionalized with ferrocene (Fc). Subsequently, this functionalized compound was combined with rGO to form a composite structure (rGO–SubPc-Fc). A laboratory-made screen-printing electrode (LabSPE) was successfully created by using carbon and silver conductive inks applied to a polycarbonate substrate through the screen-printing process. Then, the surface of LabSPE was modified with rGO–SubPc-Fc composite and made ready for the electrochemical determination of Ac. The electrochemical results revealed that the rGO–SubPc-Fc composite exhibited a remarkable sensing behavior towards the oxidation of Ac with a working range from 0.05 μM to 200 μM, and a detection limit of 0.01 μM. The selectivity of the proposed sensor (rGO–SubPc-Fc/LabSPE) for Ac detection in the presence of possible interfering compounds such as uric acid, epinephrine, ascorbic acid, dopamine, and some ions was also examined. The practical suitability of rGO–SubPc-Fc/LabSPE in real sample analysis was tested on two different types of human drug samples and appreciable recovery results were obtained in the range of 102.02–103.94 %. In drug sample analysis, the proposed method was compared with the spectrophotometric method, and satisfactory results were achieved.

Anahtar kelimeler

ACETAMINOPHEN Electrochemical sensor Ferrocene Subphthalocyanine Lab-made SPE

Atıf için künye

Alahmad, H., Yıldız Gül, E., Topaloğlu Aksoy, B., Biryan, F., Koran, K., Tanrıverdi Eçik, E., Bas, S. Z., Atacan, K., Ersoz, M., Ozmen, M., & Çoşut, B. (2025). A new lab-made screen-printed electrode system based on reduced graphene oxide-subphthalocyanine functionalized with ferrocene for electrochemical detection of acetaminophen. Microchemical Journal, 208. https://doi.org/10.1016/j.microc.2024.112434

BibTeX
@article{alahmad2025-78464,
  author = {Alahmad, Haala and Yıldız Gül, Elif and Topaloğlu Aksoy, Burcu and Biryan, Fatih and Koran, Kenan and Tanrıverdi Eçik, Esra and Bas, Salih Zeki and Atacan, Keziban and Ersoz, Mustafa and Ozmen, Mustafa and Çoşut, Bünyemin},
  title = {A new lab-made screen-printed electrode system based on reduced graphene oxide-subphthalocyanine functionalized with ferrocene for electrochemical detection of acetaminophen},
  journal = {Microchemical Journal},
  year = {2025},
  volume = {208},
  issn = {0026-265X},
  doi = {10.1016/j.microc.2024.112434},
  url = {https://akademik.atauni.edu.tr/yayinlar/78464-a-new-lab-made-screen-printed-electrode-system-based-on-reduced-graphene-oxide}
}