Atatürk Üniversitesi Atatürk Üniversitesi
Ara
Yayınlara dön
Makale Tam Makale Uluslararası 2021 Açık erişimli

Albedo parameters and effective atomic numbers of PEDOT/Carbon black composites

Demet Yılmaz, Ayşe Bayrakçeken, Tuba Özer, Fulya Memioğlu

RADIATION PHYSICS AND CHEMISTRY Cilt 182 · 01.05.2021
DOI ile aç

Özet

In this work, albedo parameters and effective atomic numbers of the PEDOT/carbon black (C) composites were determined by the gamma ray spectrometry. EDOT monomers were polymerized on carbon black (Cabot, Vulcan XC 72R) at room temperature. Ammonium persulphate (APS) was used as the oxidant. The primary dopants including polystyrene sulfonic acid (PSSA), p-toluenesulfonic acid (p-TSA) and camphor sulfonic acid (CSA) were added with the secondary ethylene glycol (EG) or DMSO dopants. Synthesized composites were physically characterized by using Raman spectroscopy in order to determine the defective sites. Albedo parameters and effective atomic numbers of PEDOT/C composites were carried out by using a HPGe detector and 59.54 keV gamma-rays emitted from a radioactive source of 241Am (59.54 keV). Compton and coherent peaks were determined at XRF spectra. It is observed that albedo parameters of the composites appear to be enhanced significantly with the CSA dopant. The impact of p-TSA dopant decreased the reflective power of the PEDOT surface. The S2 composite with low effective atomic number (Zeff.exp.=5.68) is more scatterer than the S4 composite with high effective atomic number (Zeff.exp.=6.78). It can be said that the effective atomic number results obtained by scattering experiments are more reliable than WinXCOM since the material components and geometric modeling technology for absorption are generally assumed to be uniform distribution, and parameters related to sample properties are not taken into account.

Anahtar kelimeler

mass attenuation coefficient SCATTERING MASS ATTENUATION COEFFICIENTS Effective atomic number ELEMENTS CARBON EDXRF Albedo parameter PEDOT C composite CATALYST SUPPORT GAMMA PHOTONS

Atıf için künye

Yılmaz, D., Bayrakçeken, A., Özer, T., & Memioğlu, F. (2021). Albedo parameters and effective atomic numbers of PEDOT/Carbon black composites. RADIATION PHYSICS AND CHEMISTRY, 182. https://doi.org/10.1016/j.radphyschem.2021.109378

BibTeX
@article{yilmaz2021-62834,
  author = {Yılmaz, Demet and Bayrakçeken, Ayşe and Özer, Tuba and Memioğlu, Fulya},
  title = {Albedo parameters and effective atomic numbers of PEDOT/Carbon black composites},
  journal = {RADIATION PHYSICS AND CHEMISTRY},
  year = {2021},
  volume = {182},
  issn = {0969-806X},
  doi = {10.1016/j.radphyschem.2021.109378},
  url = {https://akademik.atauni.edu.tr/yayinlar/62834-albedo-parameters-and-effective-atomic-numbers-of-pedotcarbon-black-composites}
}