The validity and reliability of the jump power app for measuring vertical jump actions in professional soccer players.
Özet
This research examines the reliability, validity, and usefulness of the Jump Power application by
comparing it with the reliable and validated Optojump photoelectric cell system in measuring squat
jump (SJ) and countermovement jump (CMJ) in professional athletes. Twenty-two soccer players
volunteered to participate in the research. The participants were the players of the U21 team in the
1st League. All athletes were subjected to SJ and CMJ tests. Jump Power app and Optojump data
were acquired simultaneously during SJ and CMJ. Trial procedure was performed on three separate
occasions (Session 1, Session 2, and Session 3), with 48 h intervals to examine the reliability of the
data from session to session. For reliability analysis, coefficients of variation percent (%CV). Jump
power app reliability values CV% is below 5%. In the validity analysis, significant differences were
observed between the Optojump photoelectric cell system and the Jump Power App for SJ and CMJ.
In conclusion, this study revealed that the Jump Power app is a reliable but not valid tool to measure
vertical jumps in soccer players.
Atıf için künye
Çetin, O., Kaya, S., Atasever, G., & Akyildiz, Z. (2024). The validity and reliability of the jump power app for measuring vertical jump actions in professional soccer players. SCIENTIFIC REPORTS, 14(1), 28801. https://doi.org/10.1038/s41598-024-78499-9
BibTeX
@article{cetin2024-310262,
author = {Çetin, Onat and Kaya, Selman and Atasever, Gökhan and Akyildiz, Zeki},
title = {The validity and reliability of the jump power app for measuring vertical jump actions in professional soccer players.},
journal = {SCIENTIFIC REPORTS},
year = {2024},
volume = {14},
number = {1},
pages = {28801},
issn = {2045-2322},
doi = {10.1038/s41598-024-78499-9},
url = {https://akademik.atauni.edu.tr/yayinlar/310262-the-validity-and-reliability-of-the-jump-power-app-for-measuring-vertical-jump}
}