Concurrent Validity of the Optojump Infrared Photocell System in Lower Limb Peak Power Assessment: Comparative Analysis with the Wingate Anaerobic Test and Sprint Performance
Özet
Aim: This study analyzed the concurrent validity of the Optojump infrared photocell system for estimating lower limb peak power by comparing it with the 15 s Wingate anaerobic test (WAnT) and examining relationships with sprint performance indicators. Methods: Twelve physically active university students (ten males, two females; age: 23.39 +/- 1.47 years; body mass: 73.08 +/- 9.19 kg; height: 173.67 +/- 6.97 cm; BMI: 24.17 +/- 1.48 kg<middle dot>m(-2)) completed a cross-sectional validation protocol. Participants performed WAnT on a calibrated Monark ergometer (7.5% body weight for males, 5.5% for females), 30 s continuous jump tests using the Optojump system (Microgate, Italy), and 30 m sprint assessments with 10 m and 20 m split times. Peak power was expressed in absolute (W), relative (W<middle dot>kg(-1)), and allometric (W<middle dot>kg(-0.67)) terms. Results: Thirty-second continuous jump testing produced systematically higher peak power values across all metrics (p < 0.001). Mean differences indicated large effect sizes: relative power (Cohen's d = 0.99; 18.263 +/- 4.243 vs. 10.99 +/- 1.58 W<middle dot>kg(-1)), absolute power (d = 0.86; 1381.71 +/- 393.44 vs. 807.28 +/- 175.45 W), and allometric power (d = 0.79). Strong correlations emerged between protocols, with absolute power showing the strongest association (r = 0.842, p < 0.001). Linear regression analysis revealed that 30 s continuous jump-derived measurements explained 71% of the variance in Wingate outcomes (R-2 = 0.710, p < 0.001). Sprint performance showed equivalent predictive capacity for both tests (Wingate: R-2 = 0.66; 30 s continuous jump: R-2 = 0.67). Conclusions: The Optojump infrared photocell system provides a valid and practical alternative to laboratory-based ergometry for assessing lower limb anaerobic power. While it systematically overestimates absolute values compared with the Wingate anaerobic test, its strong concurrent validity (r > 0.80), large effect sizes, and equivalent predictive ability for sprint performance (R-2 = 0.66-0.71) confirm its reliability as a field-based assessment tool. These findings underscore the importance of sport-specific, weight-bearing assessment technologies in modern sports biomechanics, providing coaches, practitioners, and clinicians with a feasible method for monitoring performance, talent identification, and training optimization. The results further suggest that Optojump-based protocols can bridge the gap between laboratory precision and ecological validity, supporting both athletic performance enhancement and injury prevention strategies.
Anahtar kelimeler
Atıf için künye
Khemiri, A., Negra, Y., Ceylan, H. İ., Hajri, M., Njah, A., Hachana, Y., Yildiz, M., Bayrakdaroglu, S., Muntean, R. I., & Attia, A. (2025). Concurrent Validity of the Optojump Infrared Photocell System in Lower Limb Peak Power Assessment: Comparative Analysis with the Wingate Anaerobic Test and Sprint Performance. Applied Sciences (Switzerland), 15(19). https://doi.org/10.3390/app151910741
BibTeX
@article{khemiri2025-308325,
author = {Khemiri, Aymen and Negra, Yassine and Ceylan, Halil İbrahim and Hajri, Manel and Njah, Abdelmonom and Hachana, Younes and Yildiz, Mevlut and Bayrakdaroglu, Serdar and Muntean, Raul Ioan and Attia, Ahmed},
title = {Concurrent Validity of the Optojump Infrared Photocell System in Lower Limb Peak Power Assessment: Comparative Analysis with the Wingate Anaerobic Test and Sprint Performance},
journal = {Applied Sciences (Switzerland)},
year = {2025},
volume = {15},
number = {19},
issn = {2076-3417},
doi = {10.3390/app151910741},
url = {https://akademik.atauni.edu.tr/yayinlar/308325-concurrent-validity-of-the-optojump-infrared-photocell-system-in-lower-limb-peak}
}