Improvement of the Rigid Narrow-Point Heavy Cultivator Shank Design and Analysis of Stress Distribution Using the Finite Element Method
Özet
Heavy cultivators, which are widely used under dry farming conditions, are among the secondary tillage implements
preferred for their ability to preserve soil moisture. Cultivator shanks that function by means of profound soil ripping generate
considerable draft forces depending on the tractor's forward speed, and substantial deformations occur in the main frame connections
due to the normal and shear stresses induced by these loads. It has been observed that the fastening components of fixed-shank heavy
cultivators, which are widely used in the Eastern Anatolia Region, often fail to develop sufficient resistance against shear forces. This
results in frequent damage and increased repair costs associated with the connection elements. In this study, a finite element analysis
was conducted on a cultivator shank whose design had been improved and material selection re-evaluated, taking into account the
operational field conditions under which the implement is used. Consequently, displacement and equivalent stress analyses were
conducted under static loading conditions for the shank point and its fastening components. Thereafter, the safety factor of the parts
against the applied loads was determined. The attachment of the shank point to the main frame is achieved by means of detachable
fastening elements, namely bolts. The operating speed of the tillage implement and the soil structure were considered in the
theoretical calculation of the force acting on a single shank, and an optimum mesh structure was generated accordingly. The rigid
shank point and fixed shank were defined as normalized carbon steel (C30E); the support components as structural steel (S235JR);
and the bolts as tempered steel of grade 8.8 (C45E). As demonstrated by the design improvements and analysis results, the total
displacement was found to be 0.31 mm, while the equivalent stress on the connection bolts was determined as 71.81 MPa, and the
safety factor was calculated as 8.91. It was concluded that, given the applied boundary conditions, the implemented design
improvements and material selection, the calculated maximum equivalent stresses for the fasteners are significantly lower than the
yield strength of the materials. This indicates that the cultivator leg components can operate safely.
Atıf için künye
Çomaklı, M., & Sayıncı, B. (2026). Improvement of the Rigid Narrow-Point Heavy Cultivator Shank Design and Analysis of Stress Distribution Using the Finite Element Method. Black Sea Journal of Agriculture, 9, 212–221. https://doi.org/10.47115/bsagriculture.1833758
BibTeX
@article{comakli2026-291012,
author = {Çomaklı, Mustafa and Sayıncı, Bahadır},
title = {Improvement of the Rigid Narrow-Point Heavy Cultivator Shank Design and Analysis of Stress Distribution Using the Finite Element Method},
journal = {Black Sea Journal of Agriculture},
year = {2026},
volume = {9},
pages = {212--221},
issn = {2618-6578},
doi = {10.47115/bsagriculture.1833758},
url = {https://akademik.atauni.edu.tr/yayinlar/291012-improvement-of-the-rigid-narrow-point-heavy-cultivator-shank-design-and-analysis}
}