Atatürk Üniversitesi Atatürk Üniversitesi
Ara
Yayınlara dön
Makale Tam Makale Uluslararası 2014

The efficiency of Gd- EOB- DTPA- enhanced magnetic resonance cholangiography in living donor liver transplantation: a preliminary study

Hayri OĞUL, Abdulmecit Kantarcı, Berhan PIRIMOGLU, Leyla Karaca, Bülent Aydinli, Aylin OKUR, Gürkan ÖZTÜRK, Yesim KIZRAK

Clinical Transplantation Cilt 28 · Sayı 3 · ss. 354–360 · 01.03.2014
DOI ile aç

Özet

The aim of this study was to evaluate utility of gadoxetic acid disodium (Gd-EOB-DTPA)-enhanced magnetic resonance cholangiography (MRC) for the detection of biliary complications after living donor liver transplantation (LDLT). A total of 18 patients with suspected biliary complications underwent MRC. T2-weighted MRC and contrast-enhanced MRC (CE-MRC) were used to identify the biliary complications. MRC included routine breath-hold T2-weighted MRC using half-Fourier acquisition single-shot turbo spin-echo (HASTE) sequences and Gd-EOB-DTPA-enhanced MRC T1-weighted volumetric interpolated breath-hold examination (VIBE) sequences. Before confirming the biliary complications, one observer reviewed the MRC images and the CE-MRC images separately. The verification procedures and MRC findings were compared, and the sensitivity, specificity, and accuracy of both techniques were calculated for the identification of biliary complications. The observer found six of seven biliary complications using CE-MRC. The sensitivity was 85.7% and the accuracy was 94.4%. Using MRC alone, sensitivity was 57.1% and accuracy was 55.5%. The accuracy of Gd-EOB-DTPA-enhanced MRC was superior to MRC in locating biliary leaks (p<0.05). The usage of Gd-EOB-DTPA-enhanced MRC yields information that complements the MRC findings that improve the identification of biliary complications. We recommend the use of MRC in addition to Gd-EOB-DTPA-enhanced MRC to increase the preoperative accuracy when assessing the biliary complications after LDLT.

Anahtar kelimeler

Visualization Gd-EOB-DTPA Contrast enhanced MRC MR cholangiography GADOBENATE DIMEGLUMINE biliary complications living donor liver transplantation

Atıf için künye

OĞUL, H., Kantarcı, A., PIRIMOGLU, B., Karaca, L., Aydinli, B., OKUR, A., ÖZTÜRK, G., & KIZRAK, Y. (2014). The efficiency of Gd- EOB- DTPA- enhanced magnetic resonance cholangiography in living donor liver transplantation: a preliminary study. Clinical Transplantation, 28(3), 354–360. https://doi.org/10.1111/ctr.12320

BibTeX
@article{ogul2014-230232,
  author = {OĞUL, Hayri and Kantarcı, Abdulmecit and PIRIMOGLU, Berhan and Karaca, Leyla and Aydinli, Bülent and OKUR, Aylin and ÖZTÜRK, Gürkan and KIZRAK, Yesim},
  title = {The efficiency of Gd- EOB- DTPA- enhanced magnetic resonance cholangiography in living donor liver transplantation: a preliminary study},
  journal = {Clinical Transplantation},
  year = {2014},
  volume = {28},
  number = {3},
  pages = {354--360},
  issn = {0902-0063},
  doi = {10.1111/ctr.12320},
  url = {https://akademik.atauni.edu.tr/yayinlar/230232-the-efficiency-of-gd-eob-dtpa-enhanced-magnetic-resonance-cholangiography-in}
}