Atatürk Üniversitesi Atatürk Üniversitesi
Ara
Yayınlara dön
Makale Tam Makale Uluslararası 2023

Detection of the glenoid bare spot by non-arthrographic MR imaging, conventional MR arthrography, and 3D high-resolution T1-weighted VIBE MR arthrography: comparison with CT arthrography

Mehmet Ali Ozel, Hayri Ogul, Ali Koksal, Mehmet Kose, Kutsi Tuncer, Suat EREN, Abdulmecit Kantarcı

European Radiology Cilt 33 · Sayı 5 · ss. 3276–3285 · 01.05.2023
DOI ile aç

Özet

ObjectivesTo determine the diagnostic accuracy of non-arthrographic MR imaging, conventional MR arthrography, and 3D T1-weighted volumetric interpolated breath-hold examination (VIBE) MR arthrography sequences as compared with a CT arthrography in the diagnosis of glenoid bare spot.MethodsA retrospective study of 216 patients who underwent non-arthrographic MR imaging, conventional MR arthrography, VIBE MRI arthrography, and CT arthrogram between January 2011 and March 2022 was conducted. The diagnostic accuracy of non-arthrographic MR imaging, direct MR arthrography, and VIBE MRI arthrography in the detection of glenoid bare spot was compared with that of CT arthrography. All studies were reviewed by 2 MSK radiologists. Interobserver agreement for MR imaging and MR arthrographic findings was calculated.ResultsSixteen of 216 patients were excluded. Twenty-three of 200 shoulders had glenoid bare spot on CT arthrographic images. The glenoid bare spot was detected in 11 (47.8%) and 7 (30.4%) patients on conventional non-arthrographic MR images and in 18 (78.3%) and 16 (69.6%) patients on conventional MR arthrograms by observers 1 and 2, respectively. Both observers separately described the bare spot in 22 of 23 patients (95.7%) on 3D volumetric MR arthrograms. Interobserver variabilities were fair agreement for conventional non-arthrographic MR imaging (kappa = 0.35, p < 0.05), moderate agreement for conventional MR arthrogram (kappa = 0.50, p < 0.05), and near-perfect agreement for 3D volumetric MR arthrogram reading (kappa = 0.87, p < 0.05).ConclusionsA 3D high-resolution T1-weighted VIBE MR arthrography sequence may yield diagnostic performance that is comparable with that of CT arthrography in the diagnosis of glenoid bare spot.

Anahtar kelimeler

Magnetic resonance imaging FOSSA VARIANTS Area ARTHROSCOPY TOMOGRAPHY arthrography Shoulder CARTILAGE Glenoid cavity BONE LOSS

Sürdürülebilir Kalkınma Amaçları

  • SKA 5: Cinsiyet Eşitliği

Atıf için künye

Ozel, M. A., Ogul, H., Koksal, A., Kose, M., Tuncer, K., EREN, S., & Kantarcı, A. (2023). Detection of the glenoid bare spot by non-arthrographic MR imaging, conventional MR arthrography, and 3D high-resolution T1-weighted VIBE MR arthrography: comparison with CT arthrography. European Radiology, 33(5), 3276–3285. https://doi.org/10.1007/s00330-023-09443-0

BibTeX
@article{ozel2023-230171,
  author = {Ozel, Mehmet Ali and Ogul, Hayri and Koksal, Ali and Kose, Mehmet and Tuncer, Kutsi and EREN, Suat and Kantarcı, Abdulmecit},
  title = {Detection of the glenoid bare spot by non-arthrographic MR imaging, conventional MR arthrography, and 3D high-resolution T1-weighted VIBE MR arthrography: comparison with CT arthrography},
  journal = {European Radiology},
  year = {2023},
  volume = {33},
  number = {5},
  pages = {3276--3285},
  issn = {0938-7994},
  doi = {10.1007/s00330-023-09443-0},
  url = {https://akademik.atauni.edu.tr/yayinlar/230171-detection-of-the-glenoid-bare-spot-by-non-arthrographic-mr-imaging-conventional}
}