Atatürk Üniversitesi Atatürk Üniversitesi
Ara
Yayınlara dön
Makale Tam Makale Uluslararası 2005

Transcatheter closure of patent ductus arteriosus with Nit-Occlud coils

ALPAY ÇELİKER, EBRU AYPAR, TEVFİK KARAGÖZ, EMBİYA DİLBER, Naci Ceviz

CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS Cilt 65 · Sayı 4 · ss. 569–576 · 01.08.2005
DOI ile aç

Özet

The detachable coils have been successfully used for transcatheter occlusion of small- to moderate-sized patent ductus arteriosus (PDA). We report our experience regarding the use of the Nit-Occlud coils (NOCs) for transcatheter PDA and major aortopulmonary collateral (MAPCA) occlusion. Single NCICs were used to close PDA in 26 patients, and one small and two large MAPCAs in two patients. Mean age and weight of the patients were 7.7 +/- 5.4 years and 20.6 +/- 11.6 kg. Mean minimum duct diameter was 2.8 +/- 0.8 mm; ampulla, 8.7 +/- 2.4 mm; and PDA length, 9.3 +/- 4.4 mm. Mean pulmonary artery pressure ranged from 9 to 51 mm Hg and pulmonary/systemic flow ratio from 1.1 to 5.8. Ductal shape was conical in 24 patients. Route of approach was venous in 23 and arterial in 3. Successful coil implantation was achieved in 24/26 (92.3%). Mean procedure and fluoroscopy time were 67.2 +/- 22.1 and 14.9 +/- 6.5 min. The three MAPCAs were also successfully occluded using NOC Medium and Flex. Postimplantation angiograms revealed no leak in 3, a trace or small leak in 17, and a medium leak in 4 patients. Mean follow-up was 7 5 months. Complete occlusion was achieved in 17/24 (71%) at 24 hr, 19/24 (79%) by 1 month, 13/15 (87%) by 3 months, 14/15 (93%) by 6 months, and 10/11 (90%) by 12 months postprocedure. Hemolysis, late embolization, duct recanalization, and flow disturbances were not observed. Transcatheter occlusion of moderate-sized PDAs and MAPCAs using NCICs seems to offer a safe, simple, and controlled method in pediatric patients. (c) 2005 Wiley-Liss, Inc.

Anahtar kelimeler

CHILDREN EXPERIENCE Device Patent ductus arteriosus occlusion of patent ductus arteriosus Nit-Occlud device COOK DETACHABLE COILS PERCUTANEOUS CLOSURE

Atıf için künye

ÇELİKER, A., AYPAR, E., KARAGÖZ, T., DİLBER, E., & Ceviz, N. (2005). Transcatheter closure of patent ductus arteriosus with Nit-Occlud coils. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 65(4), 569–576. https://doi.org/10.1002/ccd.20423

BibTeX
@article{celiker2005-223420,
  author = {ÇELİKER, ALPAY and AYPAR, EBRU and KARAGÖZ, TEVFİK and DİLBER, EMBİYA and Ceviz, Naci},
  title = {Transcatheter closure of patent ductus arteriosus with Nit-Occlud coils},
  journal = {CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS},
  year = {2005},
  volume = {65},
  number = {4},
  pages = {569--576},
  issn = {1522-1946},
  doi = {10.1002/ccd.20423},
  url = {https://akademik.atauni.edu.tr/yayinlar/223420-transcatheter-closure-of-patent-ductus-arteriosus-with-nit-occlud-coils}
}