Ultra-low-dose computed tomography and its utility in wrist trauma in the emergency department

Erdal Tekin, Kutsi Tuncer, İbrahim Özlü, Recep Sade, Rüstem Berhan Pirimoglu, Gokhan Polat

ACTA RADIOLOGICA Cilt 63 · Sayı 2 · ss. 192–199 · 01.02.2022
DOI ile aç

Özet

Background The use and frequency of computed tomography (CT) are increasing day by day in emergency departments (ED). This increases the amount of radiation exposed. Purpose To evaluate the image quality obtained by ultra-low-dose CT (ULDCT) in patients with suspected wrist fractures in the ED and to investigate whether it is an alternative to standard-dose CT (SDCT). Material and Methods This is a study prospectively examining 336 patients who consulted the ED for wrist trauma. After exclusion criteria were applied, the patients were divided into the study and control groups. Then, SDCT (120 kVp and 100 mAs) and ULDCT (80 kVp and 5 mAs) wrist protocols were applied simultaneously. The images obtained were evaluated for image quality and fracture independently by a radiologist and an emergency medical specialist using a 5-point scale. Results The effective radiation dose calculated for the control group scans was 41.1 +/- 2.1 mu Sv, whereas the effective radiation dose calculated for the study group scans was 0.5 +/- 0.0 mu Sv. The effective radiation dose of the study group was significantly lower than that of the control group (P < 0.01). The CT images in the study group showed no significant differences in the mean image quality score between observer 1 and observer 2 (3.4 and 4.3, respectively; P = 0.58). Both observers could detect all fractures using the ULDCT images. Conclusion ULDCT provides high-quality images in wrist traumas while reducing the radiation dose by approximately 98% compared to SDCT without any changes in diagnostic accuracy.

Anahtar kelimeler

CT DIAGNOSIS radiography FRACTURES QUALITY trauma EMERGENCY-DEPARTMENTS multidetector computed tomography Ultra-low-dose computed tomography wrist fracture PROTOCOL

Atıf için künye

Tekin, E., Tuncer, K., Özlü, İ., Sade, R., Pirimoglu, R. B., & Polat, G. (2022). Ultra-low-dose computed tomography and its utility in wrist trauma in the emergency department. ACTA RADIOLOGICA, 63(2), 192–199. https://doi.org/10.1177/0284185121989958

BibTeX
@article{tekin2022-220546,
  author = {Tekin, Erdal and Tuncer, Kutsi and Özlü, İbrahim and Sade, Recep and Pirimoglu, Rüstem Berhan and Polat, Gokhan},
  title = {Ultra-low-dose computed tomography and its utility in wrist trauma in the emergency department},
  journal = {ACTA RADIOLOGICA},
  year = {2022},
  volume = {63},
  number = {2},
  pages = {192--199},
  issn = {0284-1851},
  doi = {10.1177/0284185121989958},
  url = {https://akademik.atauni.edu.tr/yayinlar/220546-ultra-low-dose-computed-tomography-and-its-utility-in-wrist-trauma-in-the}
}