Atatürk Üniversitesi Atatürk Üniversitesi
Ara
Yayınlara dön
Makale Tam Makale Uluslararası 2015

Determination of Flurbiprofen in Human Plasma by High-Performance Liquid Chromatography

Bilal Yılmaz, Ali Fuat Erdem

JOURNAL OF CHROMATOGRAPHIC SCIENCE Cilt 53 · Sayı 9 · ss. 1443–1448 · 01.10.2015
DOI ile aç

Özet

A simple high-performance liquid chromatography method has been developed for determination of flurbiprofen in human plasma. The method was validated on an Ace C-18 column using UV detection. The mobile phase was acetonitrile-0.05 M potassium dihydrogen phosphate solution (60: 40, v/v) adjusted to pH 3.5 with phosphoric acid. The calibration curve was linear between the concentration range of 0.10-5.0 mu g/mL. Intra- and inter-day precision values for flurbiprofen in plasma were < 4.47, and accuracy (relative error) was better than 3.67%. The extraction recoveries of flurbiprofen from human plasma were between 93.0 and 98.9%. The limits of detection and quantification of flurbiprofen were 0.03 and 0.10 mu g/mL, respectively. In addition, this assay was applied to determine the pharmacokinetic parameters of flurbiprofen in six healthy Turkish volunteers who had been given 100 mg flurbiprofen.

Sürdürülebilir Kalkınma Amaçları

  • SKA 3: Sağlıklı Bireyler

Atıf için künye

Yılmaz, B., & Erdem, A. F. (2015). Determination of Flurbiprofen in Human Plasma by High-Performance Liquid Chromatography. JOURNAL OF CHROMATOGRAPHIC SCIENCE, 53(9), 1443–1448. https://doi.org/10.1093/chromsci/bmv032

BibTeX
@article{yilmaz2015-22034,
  author = {Yılmaz, Bilal and Erdem, Ali Fuat},
  title = {Determination of Flurbiprofen in Human Plasma by High-Performance Liquid Chromatography},
  journal = {JOURNAL OF CHROMATOGRAPHIC SCIENCE},
  year = {2015},
  volume = {53},
  number = {9},
  pages = {1443--1448},
  issn = {0021-9665},
  doi = {10.1093/chromsci/bmv032},
  url = {https://akademik.atauni.edu.tr/yayinlar/22034-determination-of-flurbiprofen-in-human-plasma-by-high-performance-liquid}
}