The Comparison of Computed Tomography Perfusion, Contrast-Enhanced Computed Tomography and Positron-Emission Tomography/Computed Tomography for the Detection of Primary Esophageal Carcinoma
Özet
Objective: The purpose of this study was to investigate the efficiency of computed tomography perfusion (CTP), contrast-enhanced computed tomography (CECT) and F-18-fluoro-2-deoxy-D-glucose (F-18-FDG) positron-emission tomography (PET/CT) in the diagnosis of esophageal cancer. Subjects and Methods: This prospective study consisted of 33 patients with pathologically confirmed esophageal cancer, 2 of whom had an esophageal abscess. All the patients underwent CTP, CECT and PET/CT imaging and the imaging findings were evaluated. Sensitivity, specificity and positive and negative predictive values were calculated for each of the 3 imaging modalities relative to the histological diagnosis. Results: Thirty-three tumors were visualized on CTP, 29 on CECT and 27 on PET/CT. Six tumors were stage 1, and 2 and 4 of these tumors were missed on CECT and PET/CT, respectively. Significant differences between CTP and CECT (p = 0.02), and between CTP and PET/CT (p = 0.04) were found for stage 1 tumors. Values for the sensitivity, specificity and positive and negative predictive values on CTP were 100, 100, 100 and 100%, respectively. Corresponding values on CECT were 93.94, 0, 93.94 and 0%, respectively, and those on PET/CT were 87.88, 0, 93.55 and 0%, respectively. Hence, the sensitivity, specificity and positive and negative predictive values of CTP were better than those of CECT and PET/CT. Conclusion: CTP had an advantage over CECT and PET/CT in detecting small lesions. CTP was valuable, especially in detecting stage 1 tumors. (C) 2016 S. Karger AG, Basel
Anahtar kelimeler
Sürdürülebilir Kalkınma Amaçları
-
SKA 3: Sağlıklı Bireyler
Atıf için künye
GENC, B., Kantarcı, A., SADE, R., Orsal, E., OĞUL, H., Okur, A., Aydın, Y., Karaca, L., & Eroglu, A. (2016). The Comparison of Computed Tomography Perfusion, Contrast-Enhanced Computed Tomography and Positron-Emission Tomography/Computed Tomography for the Detection of Primary Esophageal Carcinoma. MEDICAL PRINCIPLES AND PRACTICE, 25(3), 254–259. https://doi.org/10.1159/000444086
BibTeX
@article{genc2016-214153,
author = {GENC, Berhan and Kantarcı, Abdulmecit and SADE, Recep and Orsal, Ebru and OĞUL, Hayri and Okur, Aylin and Aydın, Yener and Karaca, Leyla and Eroglu, Atilla},
title = {The Comparison of Computed Tomography Perfusion, Contrast-Enhanced Computed Tomography and Positron-Emission Tomography/Computed Tomography for the Detection of Primary Esophageal Carcinoma},
journal = {MEDICAL PRINCIPLES AND PRACTICE},
year = {2016},
volume = {25},
number = {3},
pages = {254--259},
issn = {1011-7571},
doi = {10.1159/000444086},
url = {https://akademik.atauni.edu.tr/yayinlar/214153-the-comparison-of-computed-tomography-perfusion-contrast-enhanced-computed}
}