Atatürk Üniversitesi Atatürk Üniversitesi
Ara
Yayınlara dön
Makale Tam Makale Uluslararası 2015

Simple extraction method using syringe filter for detection of ethephon in tomatoes by negative-ion mode liquid chromatography with tandem mass spectrometry

Soon-Kil Cho, Ji-Mi Cho, Abdelaty Mostafa Abdelaty Hassıbelnaby, Md. Musfiqur Rahman, Jeong-Heui Choi, Young-Jun Seo, Ho-Chul Shin, Jae-Han Shim

Biomedical Chromatography Cilt 29 · Sayı 10 · ss. 1480–1485 · 01.10.2015
DOI ile aç

Özet

In this study, a simple, rapid, and sensitive method was developed for the extraction of ethephon from homogenized tomatoes that does not require a cleanup procedure. In a syringe filter, three distinct layers - aqueous, acetonitrile, and n-hexane - are clearly separated after storage at -80 degrees C for 5-10min. A Dionex IonPac column was used to separate the analyte before detection using negative-ion mode liquid chromatography with tandem mass spectrometry (LC/MS/MS). The matrix effect of the tested analyte was negligibly small and the matched calibration showed a good linearity over a concentration range of 0.01-1.0mg/kg with a correlation coefficient (R-2) of 0.9998. The recovery at three fortification levels (0.1, 0.5 and 1.0mg/kg) was between 82.9 and 108.6% with relative standard deviations (RSDs) <5.0%. The limit of quantification (0.03mg/kg) was lower than the maximum residue limit (3mg/kg) set by the Ministry of Food and Drug Safety, Republic of Korea. From a field trial, the method developed herein was applied to calculate the decline pattern and predict the pre-harvest residue limits of ethephon in tomatoes. In conclusion, the proposed sample preparation is feasible for the detection of hydrophilic analytes in tomatoes. Copyright (c) 2015 John Wiley & Sons, Ltd.

Anahtar kelimeler

EXTRACTION Method validation gas chromatography TANDEM MASS-SPECTROMETRY analysis TOMATO RESIDUES Apples Residue plant growth regulator

Atıf için künye

Cho, S., Cho, J., Hassıbelnaby, A. M. A., Rahman, M. M., Choi, J., Seo, Y., Shin, H., & Shim, J. (2015). Simple extraction method using syringe filter for detection of ethephon in tomatoes by negative-ion mode liquid chromatography with tandem mass spectrometry. Biomedical Chromatography, 29(10), 1480–1485. https://doi.org/10.1002/bmc.3446

BibTeX
@article{cho2015-209746,
  author = {Cho, Soon-Kil and Cho, Ji-Mi and Hassıbelnaby, Abdelaty Mostafa Abdelaty and Rahman, Md. Musfiqur and Choi, Jeong-Heui and Seo, Young-Jun and Shin, Ho-Chul and Shim, Jae-Han},
  title = {Simple extraction method using syringe filter for detection of ethephon in tomatoes by negative-ion mode liquid chromatography with tandem mass spectrometry},
  journal = {Biomedical Chromatography},
  year = {2015},
  volume = {29},
  number = {10},
  pages = {1480--1485},
  issn = {0269-3879},
  doi = {10.1002/bmc.3446},
  url = {https://akademik.atauni.edu.tr/yayinlar/209746-simple-extraction-method-using-syringe-filter-for-detection-of-ethephon-in}
}