Atatürk Üniversitesi Atatürk Üniversitesi
Ara
Yayınlara dön
Makale Tam Makale Uluslararası 2016

Residue level and dissipation pattern of lepimectin in shallots using high-performance liquid chromatography coupled with photodiode array detection

Sung-Woo Kim, Md. Musfiqur Rahman, Abdelaty Mostafa Abdelaty Hassıbelnaby, Lieu T. B. Truong, Jeong-Heui Choi, Joon-Seong Park, Mi-Ra Kim, Ho-Chul Shin, Jae-Han Shim

Biomedical Chromatography Cilt 30 · Sayı 11 · ss. 1835–1842 · 01.11.2016
DOI ile aç

Özet

Lepimectin, as an emulsifiable concentrate, was sprayed on shallots at the recommended dose rate (10mL/20L) to determine its residue levels, dissipation pattern, pre-harvest residue limits (PHRLs), and health risk. Samples were randomly collected over 10days, extracted with acetonitrile, purified using an amino solid-phase extraction (NH2-SPE) cartridge and analyzed using a high-performance liquid chromatography-photodiode array detection method. Field-incurred samples were confirmed using ultra-performance liquid chromatography-tandem mass spectrometry. The linearity was excellent, with a determination coefficient (R-2) of 0.9991. The recoveries at two spiking levels (0.2 and 1.0mg/kg) ranged from 84.49 to 87.64% with relative standard deviations of 7.04%. The developed method was applied to field samples grown in separate greenhouses, one located in Naju and one in Muan, in the Republic of Korea. The dissipation pattern was described by first-order kinetics with half-lives of 1.9 (Naju) and 1.7days (Muan). The PHRL curves indicated that, if the lepimectin residues are <0.18 (Naju) and <0.13mg/kg (Muan) 5days before harvest, the residue levels will be lower than the maximum residue limit (0.05mg/kg) upon harvesting. The risk assessment data indicated that lepimectin is safe for use in the cultivation of shallots, with no risk of detrimental effects to the consumer.

Anahtar kelimeler

PERSISTENCE BEHAVIOR LIQUID-CHROMATOGRAPHY drug Natural products TANDEM MASS-SPECTROMETRY PESTICIDE insecticides SOILS dissipation pattern Pre-harvest residue limit lepimectin shallots ONTARIO

Sürdürülebilir Kalkınma Amaçları

  • SKA 3: Sağlıklı Bireyler

Atıf için künye

Kim, S., Rahman, M. M., Hassıbelnaby, A. M. A., Truong, L. T. B., Choi, J., Park, J., Kim, M., Shin, H., & Shim, J. (2016). Residue level and dissipation pattern of lepimectin in shallots using high-performance liquid chromatography coupled with photodiode array detection. Biomedical Chromatography, 30(11), 1835–1842. https://doi.org/10.1002/bmc.3759

BibTeX
@article{kim2016-209709,
  author = {Kim, Sung-Woo and Rahman, Md. Musfiqur and Hassıbelnaby, Abdelaty Mostafa Abdelaty and Truong, Lieu T. B. and Choi, Jeong-Heui and Park, Joon-Seong and Kim, Mi-Ra and Shin, Ho-Chul and Shim, Jae-Han},
  title = {Residue level and dissipation pattern of lepimectin in shallots using high-performance liquid chromatography coupled with photodiode array detection},
  journal = {Biomedical Chromatography},
  year = {2016},
  volume = {30},
  number = {11},
  pages = {1835--1842},
  issn = {0269-3879},
  doi = {10.1002/bmc.3759},
  url = {https://akademik.atauni.edu.tr/yayinlar/209709-residue-level-and-dissipation-pattern-of-lepimectin-in-shallots-using-high}
}