Treatment of Olive Mill Wastewater with Electro-Oxidation Method
Özet
Advanced oxidation processes are an efficient method of treating many industrial wastewaters. This study investigated the treatment of olive mill wastewater with the electro-oxidation method. This study investigated data obtained from chemical oxygen demand (COD), total organic carbon (TOC) and total phenol (TP) removal efficiencies for this wastewater. The anode material was Ti/Pt while the cathode material was Ti. The experiments using a batch reactor examined the effects of mixing rate (0-600 rpm), dilution factor (1/5-5/5), pH (2-8), type of support electrolyte (Na2SO4, KCl and NaCl), concentration of support electrolyte (0.25-1.25 M) and current density (2.5-15 mA/cm(2)) on COD, TOC and TP removal efficiencies. The study found the COD, TOC and TP removal rates under optimum conditions were 100%, 78% and 100%. (C) 2015 The Electrochemical Society. All rights reserved.
Sürdürülebilir Kalkınma Amaçları
-
SKA 6: Temiz Su ve Sıhhi Koşullar
Atıf için künye
KUL, S., Boncukcuoglu, R., Yılmaz, A. E., & Fil, B. A. (2015). Treatment of Olive Mill Wastewater with Electro-Oxidation Method. JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 162(8). https://doi.org/10.1149/2.0451508jes
BibTeX
@article{kul2015-179396,
author = {KUL, Sinan and Boncukcuoglu, Recep and Yılmaz, Alper Erdem and Fil, Baybars Ali},
title = {Treatment of Olive Mill Wastewater with Electro-Oxidation Method},
journal = {JOURNAL OF THE ELECTROCHEMICAL SOCIETY},
year = {2015},
volume = {162},
number = {8},
issn = {0013-4651},
doi = {10.1149/2.0451508jes},
url = {https://akademik.atauni.edu.tr/yayinlar/179396-treatment-of-olive-mill-wastewater-with-electro-oxidation-method}
}