Stress Distributions Created by Short and Regular Implants Placed in the Anterior Maxilla at Different Angles: A Finite Element Analysis
Özet
Although short implants are seen as alternative treatments that require
additional surgical techniques in posterior region, they can be applied
to anterior maxilla and various studies are required on this subject.
The purpose of this study was to examine and compare the peak von Mises
stress distributions in the crown, implant and abutment by using finite
element analysis (FEA). Besides, a comparison of the implant-abutment
connection types in the short implant with the FEA method was
established. A short implant (4 × 5 mm) with a taper-lock connection and
a regular implant (4 × 9 mm) with a screw connection were used in
maxillary central incisor tooth area. Three different titanium abutments
with 0?, 15? and 25? angles were used for abutments. In addition, in
order to determine whether the stress change in short implants is due to
the length of the implant-abutment connection, a screw was designed for
a short implant and it was also evaluated in the same three angles. A
total of three groups and nine models were generated. 114.6N load was
applied to the cingulum area of the crown at an angle of 135? to the
long axis of the crowns. A torque load of 25 Ncm was applied to the
regular and short implant screw. Von Mises stress distributions of
implants, abutments and crowns were evaluated by using FEA. Increased
angle in implants increased von Mises stress values of implant, abutment
and crown. Screw connection was found higher at all angles in short
implants. Close values were found at different angles in taper-lock
short implant crowns. The length and the angle in the bone of implant
with the type of implant-abutment connection results in the accumulated
stress values. Clinical Implications Taper implant-abutment connection
system was found to be more promising in terms of stress accumulation in
crowns. Although the amount of stress on the abutment increased due to
the length of the implant in short implants, taper implant-abutment
connection system slightly reduced related to this increase.
Atıf için künye
Özmen, M. F., & Bayındır, F. (2023). Stress Distributions Created by Short and Regular Implants Placed in the Anterior Maxilla at Different Angles: A Finite Element Analysis. Open Journal of Stomatology, 13. https://doi.org/10.4236/ojst.2023.131004
BibTeX
@article{ozmen2023-14760,
author = {Özmen, Mehmet Fatih and Bayındır, Funda},
title = {Stress Distributions Created by Short and Regular Implants Placed in the Anterior Maxilla at Different Angles: A Finite Element Analysis},
journal = {Open Journal of Stomatology},
year = {2023},
volume = {13},
issn = {2160-8709},
doi = {10.4236/ojst.2023.131004},
url = {https://akademik.atauni.edu.tr/yayinlar/14760-stress-distributions-created-by-short-and-regular-implants-placed-in-the}
}