Atatürk Üniversitesi Atatürk Üniversitesi
Ara
Yayınlara dön
Makale Tam Makale Uluslararası 2022

Assessing the Effect of Interimplant Distance and Angle on Different Impression Techniques

Berkman Albayrak, İsmail Hakkı Korkmaz, Alvin G. Wee, Cortino Sukotjo, Funda Bayındır

Machines Cilt 10 · Sayı 5 · 01.05.2022
DOI ile aç

Özet

© 2022 by the authors. Licensee MDPI, Basel, Switzerland.We aimed to evaluate the trueness of digital and conventional impression techniques based on different angles and distances between implants and the deviation caused by the angle and distance parameters varying between implants. Eight implants were placed in a polyurethane edentulous mandibular model at different angles and distances. After obtaining a 3-dimensional (3D) reference model by using an optical scanner, the model was scanned with three intraoral scanners: Cerec Omnicam (DO), Trios 3 (DT), and Carestream 3500 (DC). Then, the master casts obtained from the conventional impressions (C) were also digitized, and all impression data were imported into reverse engineering software to be compared with the 3D reference model. Distance and angle measurements between adjacent implants were performed, and the data were analyzed with ANOVA– Tukey and Kruskal Wallis tests. The significance level was accepted as p < 0.05. While DT and C groups gave the best results for high interimplant distances, the trueness of intraoral scanners was found to be superior to the conventional method between closer implants. At higher angulations, the angular trueness of C group was found to be significantly lower. At short distances, digital groups showed superiority, and the trueness of conventional impression decreased with higher angulations.

Anahtar kelimeler

ANGLE ACCURACY digital implant impression interimplant distance intraoral scanner trueness CONVENTIONAL IMPLANT IMPRESSIONS DIGITAL IMPRESSION REHABILITATION TECHNOLOGY ANGULATION PROSTHESES FRAMEWORK

Atıf için künye

Albayrak, B., Korkmaz, İ. H., Wee, A. G., Sukotjo, C., & Bayındır, F. (2022). Assessing the Effect of Interimplant Distance and Angle on Different Impression Techniques. Machines, 10(5). https://doi.org/10.3390/machines10050293

BibTeX
@article{albayrak2022-14649,
  author = {Albayrak, Berkman and Korkmaz, İsmail Hakkı and Wee, Alvin G. and Sukotjo, Cortino and Bayındır, Funda},
  title = {Assessing the Effect of Interimplant Distance and Angle on Different Impression Techniques},
  journal = {Machines},
  year = {2022},
  volume = {10},
  number = {5},
  issn = {2075-1702},
  doi = {10.3390/machines10050293},
  url = {https://akademik.atauni.edu.tr/yayinlar/14649-assessing-the-effect-of-interimplant-distance-and-angle-on-different-impression}
}