Atatürk Üniversitesi Atatürk Üniversitesi
Ara
Yayınlara dön
Makale Tam Makale Uluslararası 2025

CF-PEEK vs. Titanium Dental Implants: Stress Distribution and Fatigue Performance in Variable Bone Qualities

Nurdan Polat Sağsöz, Fahri Murat, Sema Nur Sevinç Gül, Abdullah Tahir Şensoy, Irfan Kaymaz

Biomimetics Cilt 10 · Sayı 9 · 01.09.2025
DOI ile aç

Özet

This study aims to evaluate the biomechanical behavior of titanium and carbon fiber-reinforced polyetheretherketone (CF-PEEK) dental implants under varying bone densities and loading conditions using finite element analysis (FEA). A single-tooth mandibular molar implant system was modeled, comprising titanium or CF-PEEK abutment and fixture, and surrounding bone structures with four configurations: (I) fully cortical bone, (II) 2 mm cortical layer with trabecular bone, (III) 1 mm cortical with high-density trabecular bone, and (IV) 1 mm cortical with low-density trabecular bone. Vertical and oblique static loads of 100 N were applied to simulate masticatory forces. FEA results revealed that titanium implants exhibited higher von Mises stress values in the implant and abutment under oblique loading, exceeding 400 MPa, while CF-PEEK components showed reduced stress but significantly higher strain levels. Cortical and trabecular bone surrounding CF-PEEK implants received more uniform stress distribution, potentially minimizing stress shielding effects. However, fatigue life analyses indicated that CF-PEEK abutment and screw components were more susceptible to mechanical failure under oblique loads, particularly in low-density bone models. In conclusion, CF-PEEK implants offer a more physiological load transfer to bone and reduced stress shielding compared to titanium. However, their structural reliability under complex loading, especially in low-quality bone conditions, requires careful consideration. These findings support the potential use of CF-PEEK in select clinical scenarios but highlight the need for further material and design optimization.

Anahtar kelimeler

Dental implants bone density CF-PEEK fatigue analysis finite element analysis (FEA)

Atıf için künye

Polat Sağsöz, N., Murat, F., Sevinç Gül, S. N., Şensoy, A. T., & Kaymaz, I. (2025). CF-PEEK vs. Titanium Dental Implants: Stress Distribution and Fatigue Performance in Variable Bone Qualities. Biomimetics, 10(9). https://doi.org/10.3390/biomimetics10090619

BibTeX
@article{polatsagsoz2025-13620,
  author = {Polat Sağsöz, Nurdan and Murat, Fahri and Sevinç Gül, Sema Nur and Şensoy, Abdullah Tahir and Kaymaz, Irfan},
  title = {CF-PEEK vs. Titanium Dental Implants: Stress Distribution and Fatigue Performance in Variable Bone Qualities},
  journal = {Biomimetics},
  year = {2025},
  volume = {10},
  number = {9},
  issn = {2313-7673},
  doi = {10.3390/biomimetics10090619},
  url = {https://akademik.atauni.edu.tr/yayinlar/13620-cf-peek-vs-titanium-dental-implants-stress-distribution-and-fatigue-performance}
}