Atatürk Üniversitesi Atatürk Üniversitesi
Ara
Yayınlara dön
Makale Tam Makale Uluslararası 2016

Cyclic fatigue analysis of Reciproc R25® instruments with different kinematics.

Hakan Arslan, Meltem Sümbüllü, Ezgi Doganay, Ertuğrul Karataş, Ismail Davut Capar, Huseyin Ertas

Australian endodontic journal : the journal of the Australian Society of Endodontology Inc Cilt 42 · Sayı 1 · ss. 22 · 01.04.2016
DOI ile aç

Özet

This study aimed to compare the cyclic fatigue resistance of Reciproc (R) instruments when used with different kinematics (150 degrees counterclockwise (CCW)-30 degrees clockwise (CW), 270 degrees CCW-30 degrees CW, 360 degrees CCW-30 degrees CW and continuous rotation). Various kinematics were tested in steel canals with a 3mm radius and a 60 degrees angle of curvature as follows (n=20): 150 degrees CCW-30 degrees CW, 270 degrees CCW-30 degrees CW, 360 degrees CCW-30 degrees CW and 360 degrees CCW (rotary motion). Reciproc R25 (R) instruments were used until fracture occurred. The time to fracture was recorded in seconds. The data were statistically analysed using a one-way analysis of variance and Tukey's post-hoc tests (P=.05). The cyclic fatigue resistance of Reciproc R25 (R) instruments used with various kinematics in decreasing order was as follows: 150 degrees CCW-30 degrees CW>270 degrees CCW-30 degrees CW=360 degrees CCW-30 degrees CW>360 degrees CCW rotary motion. The 150 degrees CCW-30 degrees CW reciprocating motion had the best performance in time to fracture. All reciprocating motions (150 degrees CCW-30 degrees CW, 270 degrees CCW-30 degrees CW and 360 degrees CCW-30 degrees CW) resulted in a longer mean duration to failure compared with the 360 degrees CCW rotary motion.

Anahtar kelimeler

DEFECTS cyclic fatigue kinematics movement reciprocation root canal instrumentation rotary TITANIUM ROTARY SYSTEMS ROOT-CANAL PREPARATION PROTAPER SYSTEM FILES

Atıf için künye

Arslan, H., Sümbüllü, M., Doganay, E., Karataş, E., Capar, I. D., & Ertas, H. (2016). Cyclic fatigue analysis of Reciproc R25® instruments with different kinematics. Australian endodontic journal : the journal of the Australian Society of Endodontology Inc, 42(1), 22. https://doi.org/10.1111/aej.12115

BibTeX
@article{arslan2016-11921,
  author = {Arslan, Hakan and Sümbüllü, Meltem and Doganay, Ezgi and Karataş, Ertuğrul and Capar, Ismail Davut and Ertas, Huseyin},
  title = {Cyclic fatigue analysis of Reciproc R25® instruments with different kinematics.},
  journal = {Australian endodontic journal : the journal of the Australian Society of Endodontology Inc},
  year = {2016},
  volume = {42},
  number = {1},
  pages = {22},
  issn = {1329-1947},
  doi = {10.1111/aej.12115},
  url = {https://akademik.atauni.edu.tr/yayinlar/11921-cyclic-fatigue-analysis-of-reciproc-r25-instruments-with-different-kinematics}
}