Abstract

Low-flow anesthesia aims to minimize anesthetic gas consumption while maintaining adequate anesthesia. To examine the effects of minimal-flow anesthesia on perioperative lung dynamics and postoperative pulmonary function tests, a prospective, randomized controlled study was conducted between October 2023 and March 2024 at Atat & uuml;rk University. A total of 66 patients (15 males, 45 females) with confirmed American Society of Anesthesiologists (ASA) grade I-II, aged 18-65 years, and scheduled for elective laparoscopic cholecystectomy were included in the study. Patients were randomized into two groups: MeFA (medium flow anesthesia, 2 L/min fresh gas flow) and MiFA (minimal flow anesthesia, 0.5 L/min fresh gas flow). In both groups, dynamic compliance values, peak inspiratory pressure (PIP) values, total inhalation anesthetic drug consumption, total remifentanil drug consumption, duration of anesthesia, duration of surgery, and spirometry test results were recorded. Respiratory measurements were recorded at the 5(th) minute after intubation (T1), 5(th) (T2), 10(th) (T3), 30(th) (T4), and 60(th) (T5) minutes after surgical incision and immediately after the surgical suturing (T6) pulse. There was no significant difference in compliance or PIP values between the groups from T1 to T5 (P > 0.05). However, at T6, the MeFA group exhibited a significant decrease in compliance and an increase in PIP compared with the MiFA group (P < 0.05). Additionally, significant differences in compliance and PIP values were found across all time intervals compared with those at T1, except for the T5-6 compliance values in the MiFA group (P < 0.001). No significant difference in respiratory function test values was noted between the groups (P > 0.05). The MiFA group exhibited a relatively milder reduction in compliance values and a lesser elevation in PIP values. Compared with medium-flow anesthesia, minimal-flow anesthesia may help mitigate perioperative lung function deterioration. These findings suggest potential benefits in preserving lung mechanics, warranting further research. This trial was registered at clinicaltrials.gov (identifier No. NCT06055335, registered March 25, 2023).

Keywords
anesthesia anesthetic gases cholecystectomy compliance laparoscopy low-flow anesthesia lung function tests peak inspiratory pressure postoperative surgery LAPAROSCOPIC CHOLECYSTECTOMY
WoS Categories
Medicine, Research & Experimental
Citation
Journal
MEDICAL GAS RESEARCH
Year
2026
Volume
16
Issue
2
Pages
110-115
ISSN
2045-9912
DOI
10.4103/mgr.MEDGASRES-D-25-00037
WoS UID
WOS:001553040300013
Open via DOI