Article 2025 · 0 citations

Evaluation with finite element analysis of a ball attachment overdenture prosthesis of a patient

Ozdemir, Hatice, Hulagu, Burak

Abstract

This study aimed to apply finite element analysis (FEA) to simulate the oral environment of a patient with an implant-supported overdenture prosthesis. A 3D mandibular model was created for a 45-year-old female patient from CT images, with mucosal thickness measured at 3 mm on average using ultrasonography. The overdenture prosthesis was scanned with an intraoral scanner and placed onto the 3D mandibular model. Displacement of the prosthesis and von Mises stress values of the implant, surrounding bone tissue, implant-prosthesis components, and mucosa were calculated under various masticatory loads. The study found that anterior mastication generated higher stress compared to unilateral and bilateral mastication. The addition of a third implant significantly reduced stress and improved prosthesis stability, particularly during bilateral mastication.

Keywords
Finite element analysis Ball attachment Overdenture MANDIBULAR 2-IMPLANT OVERDENTURES PERI-IMPLANT BONE QUALITY-OF-LIFE COMPLETE DENTURE METAANALYSIS MECHANOSTAT HEIGHT NUMBER
WoS Categories
Dentistry, Oral Surgery & Medicine Materials Science, Biomaterials
Sustainable Development Goals
Citation
Journal
DENTAL MATERIALS JOURNAL
Year
2025
Volume
44
Issue
1
Pages
112-120
ISSN
0287-4547
DOI
10.4012/dmj.2024-252
WoS UID
WOS:001533924600014
Open via DOI