language Türkçe
Article 2024 · 6 citations

Two-Emission Channel Hybrid Nanosensors Based on BODIPY-Appended Nanocrystalline Cellulose for Determination of Biothiols

Omeroglu, Ipek, Sanko, Vildan, Senocak, Ahmet, Tumay, Sureyya Oguz

Abstract

The amounts of cysteine (Cys), homocysteine (Hcy), and glutathione (GSH), which are biothiols that have an important role in biological organisms in living systems, are associated with many diseases or dysfunctions. In this study, hybrid nanosensors based on the boron-dipyrromethene (BODIPY)-appended nanocrystalline cellulose (NCC) platform with two emission channels (<bold>3</bold>, <bold>4</bold>) have been designed and applied to determine biothiols in the real sample for the first time. The chemical and morphological characterizations of the prepared compounds (mono-(<bold>1</bold>), distyryl-BODIPY (<bold>2</bold>)) and target NCC-based fluorescence hybrid materials (<bold>3</bold>, <bold>4</bold>)) were performed, and the optimum conditions for the detection procedures of biothiols were determined. After treatment with biothiols, an intramolecular rearrangement reaction resulted in the removal of 4-chloro-7-nitrobenzofurazan (NBD) from the structure and the fluorophores mono- and distyryl-BODIPYs were released in the nanostructures simultaneously. Moreover, the nanosensor systems cause an increase in sensitivity and selectivity through the increased surface area and the presence of an increased number of binding sites due to the surface-modified NBD-based fluorophore groups. The two emission channels with various response ratios <bold>3</bold> and <bold>4</bold> were used as analytical signals for distinguishing GSH, Cys, and Hcy. The detection limits for biothiols were determined between 5.0 and 90.0 nmol L-1 with wide linear working ranges for <bold>3</bold> and <bold>4</bold> within a few seconds. The accuracy of the determination methods presented based on <bold>3</bold> and <bold>4</bold> was evaluated using a spike/recovery test and high-performance liquid chromatography (HPLC). After assessing the accuracies of <bold>3</bold> and <bold>4</bold>, discriminative determination of trace levels of Hcy, Cys, and GSH was successfully carried out in a simulated human serum sample. Importantly, RGB-based practical applications of hybrid nanosensors (<bold>3</bold> and <bold>4</bold>) were competently utilized by fabricated paper-based detection kits for biothiols.

Keywords
nanosensor hybrid material biothiols fluorescence real sample BODIPY nanocrystallinecellulose RGB FLUORESCENT-PROBE BENZOFURAZAN STRUCTURE FLUOROGENIC REAGENTS LIVING CELLS GLUTATHIONE CYSTEINE DISCRIMINATION CYSTEINE/HOMOCYSTEINE NANOPARTICLES HOMOCYSTEINE
WoS Categories
Nanoscience & Nanotechnology Materials Science, Multidisciplinary
Sustainable Development Goals
Citation
Journal
ACS APPLIED NANO MATERIALS
Year
2024
Volume
7
Issue
18
Pages
21420-21435
eISSN
2574-0970
DOI
10.1021/acsanm.4c03168
WoS UID
WOS:001310087600001
Open via DOI