An experimental work on radiation scattering features of some thermoluminescent dosimetry materials

Yilmaz, Demet, Akkus, Tuba

Abstract

In this study, albedo parameters are experimentally measured to determine radiation scattering features of some thermoluminescent dosimetry materials (TLD 100, TLD 100h, TLD 200 and TLD 400). In experimental setup, it was used scattering angle of 168 degrees, 59.54 keV gamma rays and HPGe detector. The effective atomic numbers of the investigated materials were determined from the coherent to Compton scattering intensity ratio. Also, the mass attenuation coefficient, the mass energy absorption coefficient and kerma relative to air and ICRU tissue were calculated for the TLD materials. It was observed that TLD 100h is the best tissue equivalent material among other TLD materials and best reflects 59.54 keV gamma rays.

Keywords
Thermoluminescent dosimetry material Albedo parameters Effective atomic number Coherent scattering Compton scattering Kerma ENERGY ABSORPTION-COEFFICIENTS MASS ATTENUATION COEFFICIENT KERMA
WoS Categories
Chemistry, Physical Nuclear Science & Technology Physics, Atomic, Molecular & Chemical
Citation
Journal
RADIATION PHYSICS AND CHEMISTRY
Year
2024
Volume
216
ISSN
0969-806X
eISSN
1879-0895
DOI
10.1016/j.radphyschem.2023.111456