language English
Article Early Access 2025 · 2 atıf

Assessing readability and accuracy of content produced by the American College of Prosthodontists and large language models for patient education in prosthodontics

Prasad, Soni, Koseoglu, Merve, Antonopoulou, Stavroula, Huber, Heidi Marie, Azarbal, Atousa, Kurniawan, Sri, Sukotjo, Cortino

Özet

Purpose: This study aims to evaluate the readability and accuracy of content produced by ChatGPT, Copilot, Gemini, and the American College of Prosthodontists (ACP) for patient education in prosthodontics. Materials and Methods: A series of 26 questions were selected from the ACP's list of questions (GoToAPro.org FAQs) and their published answers. Answers to the same questions were generated from ChatGPT-3.5, Copilot, and Gemini. The word counts of responses from chatbots and the ACP were recorded. The readability was calculated using the Flesch Reading Ease Scale and Flesch-Kincaid Grade Level. The responses were also evaluated for accuracy, completeness, and overall quality. Descriptive statistics were used to calculate mean and standard deviations (SD). One-way analysis of variance was performed, followed by the Tukey multiple comparisons to test differences across chatbots, ACP, and various selected topics. The Pearson correlation coefficient was used to examine the relationship between each variable. Significance was set at alpha < 0.05. Results: ChatGPT had a higher word count, while ACP had a lower word count (p < 0.001). The cumulative scores of the prosthodontist topic had the lowest Flesch Reading Ease Scale score, while brushing and flossing topics displayed the highest score (p < 0.001). Brushing and flossing topics also had the lowest Flesch-Kincaid Grade Level score, whereas the prosthodontist topic had the highest score (p < 0.001). Accuracy for denture topics was the lowest across the chatbots and ACP, and it was the highest for brushing and flossing topics (p = 0.006). Conclusions: This study highlights the potential for large language models to enhance patient's prosthodontic education. However, the variability in readability and accuracy across platforms underscores the need for dental professionals to critically evaluate the content generated by these tools before recommending them to patients.

Anahtar Kelimeler
accuracy dentures implants prosthodontics readability READING-ABILITY HEALTH LEVEL
WoS Kategorileri
Dentistry, Oral Surgery & Medicine
Sürdürülebilir Kalkınma Amaçları
Künye
Dergi
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY
Yıl
2025
ISSN
1059-941X
eISSN
1532-849X
DOI
10.1111/jopr.70022
WoS UID
WOS:001556108700001
Yayını aç (DOI)