language English
Article 2024 · 8 atıf

Experimental and numerical investigation on fluid flow and heat transfer behaviour of foam cladded pin fin heat sink

Guler, Nursel, Bayer, Ozgur, Solmaz, Ismail

Özet

As technology advances, there is a growing demand for more efficient cooling solutions in electronics. Open-cell metal foams offer a unique solution, combining the strength of metals with the characteristics of foams, including being lightweight and having a high heat transfer area-to-volume ratio. Fully covering heatsinks with porous materials results in high pressure drop values, which is undesirable for electronics cooling. This study proposes a novel design that incorporates cladded aluminum foams on the pin fins within a heatsink. The hydrothermal performance of the proposed design is experimentally and numerically investigated. The results indicate that increasing the cladding thickness enhances heat transfer performance while increasing the pressure drop. For a heatsink with a pin fin diameter of 5 mm at the Reynolds number of 1121, the foam thickness of 5 mm depicts 46.5 % higher hydrothermal performance compared to a pin fin heatsink without porous while a fully porous covered heatsink depicts 38.9 % higher hydrothermal performance.

Anahtar Kelimeler
Cooling of electronic components Heat sink Open-cell metal foam Foam cladded pin fin METAL FOAM FORCED-CONVECTION PERFORMANCE MANAGEMENT
WoS Kategorileri
Thermodynamics Energy & Fuels Engineering, Mechanical Mechanics
Künye
Dergi
APPLIED THERMAL ENGINEERING
Yıl
2024
Cilt
256
ISSN
1359-4311
eISSN
1873-5606
DOI
10.1016/j.applthermaleng.2024.124184
WoS UID
WOS:001298089900001
Yayını aç (DOI)