OPTIMIZATION OF FINNED HEAT SINKS WITH ELECTROSPRAY COOLING: FULL FACTORIAL METHOD
In this study, the optimum heat sink geometry was determined by the full factorial method with electrospray cooling, which has started to find a place among the methods used for the removal of high heat flux in recent years. The experiments were carried out at 4.4 kV voltage, 0.2 mL/min flow rate, di = 0.61 mm nozzle diameter, and 20 mm nozzle -to -heat sink distance. Ethanol was used as the cooling fluid. The experiments were carried out in the cone jet electrospray mode. As a result of the experiments performed with square, rectangular, and triangular fin heat sinks, it was determined that the best cooling performance was achieved in the square fin heat sink. As a result of the experiments carried out with the square fin heat sink with 27 different geometries, it was determined that the most effective cooling was achieved in the Square -18 heat sink with 3 mm fin width, 3 mm fin distance, and 3 mm fin height. An average temperature value of 51degree celsius and a fin enhancement ratio of 1.11 were obtained for eight different heat fluxes (3.2-2.99-2.75-2.59-2.4-2.19-2.02-1.88 kW/m(2)) in the Square -18 heat sink.
- Dergi
- HEAT TRANSFER RESEARCH
- Yıl
- 2024
- Cilt
- 55
- Sayı
- 6
- Sayfa
- 47-64
- ISSN
- 1064-2285
- eISSN
- 2162-6561
- DOI
- 10.1615/HeatTransRes.2023049860
- WoS UID
- WOS:001196727600002