language English
Article 2024 · 6 atıf

Fire resistance of concrete-filled steel tube beam-column under elevated temperatures and cyclic loading

Bayrak, Baris, Maali, Mahyar, Kilic, Mahmut, Maali, Merve, Aydin, Abdulkadir Cuneyt

Özet

This article aims to provide an overview of the fire resistance of concrete-filled steel tube beam columns and the importance of fire resistance in building design and construction. Ten experimental models were developed to predict the behavior of different types of concrete-filled steel tubes and beams-columns under Fire resistance conditions (ISO-834) under cyclic loading in two groups. The results show the type of concrete effect on moment-rotation characteristics. Also, increasing the length of the stiffener on the column increases the load and moment capacity, but also affects the failure mode. Moreover, the ideal situation is to use PP fiber concrete in concrete-filled steel tube structural elements where displacement and rotation capacity are prominent. Withal, the recycling of fire-exposed steel beam-to-column tube element is available by filling the inner space with C50 and/or polypropylene fiber reinforced concrete, also as a fireproof member.

Anahtar Kelimeler
composite cyclic load geopolymer concrete ISO-834 standard fire steel tube TUBULAR COLUMNS PERFORMANCE BEHAVIOR
WoS Kategorileri
Construction & Building Technology Engineering, Civil
Sürdürülebilir Kalkınma Amaçları
Künye
Dergi
STRUCTURAL CONCRETE
Yıl
2024
Cilt
25
Sayı
5
Sayfa
3145-3163
ISSN
1464-4177
eISSN
1751-7648
DOI
10.1002/suco.202301121
WoS UID
WOS:001192167900001
Yayını aç (DOI)