language English
Article 2023 · 2 atıf

Investigation of the water quality of Aktutan pond located in Gumushane province in the North East region of Turkey by Hazen statistical method

Oskay, Volkan, Karagoz, Ozlem, Kuslu, Soner

Özet

Water is an inevitable need for living things to survive. However, due to the decrease in water resources due to global climate change, it is estimated that one of the biggest problems of the last century will be water scarcity. Water scarcity is directly related to the ratio of usable water to the population. Today, the quality of water is very important as well as the amount of water. In this study, water quality of the Aktutan Pond feeding the Bahcecik dam meeting the drinking water needs of Gumushane province was investigated using the Hazen statistical method (HSM). For this purpose, water samples were taken from three different points of the Aktutan pond every month (except January) in 2016, 2017 and 2018.The parameters examined in accordance with international standards and using the HSM are as follows: pH, temperature, electrical conductivity (EC), color, dissolved oxygen (DO), chemical oxygen demand (COD), biochemical oxygen demand (BOD5), total organic carbon (TOC), nitrogen group, suspended solid matter (SSM), anion groups, oil-grease, phosphorus group, cation groups, hydrocarbons, methylene blue active matter (MBAM), cyanide (CN-), total pesticides, phenols, polycyclic aromatic hydrocarbons (PAH), heavy metals. The surface water quality of Aktutan stream was classified by the "Regulation on the Quality and Purification of Drinking Water Supply (RQPDWS)" and "Regulation Amending the Regulation on Surface Water Quality (RARSWQ)". According to RQPDWS; PAH is in the A2 quality class. NO3-, F-, SO42-, Cl-, o-PO43-, CN-, Pesticide, Se, Cu, Zn, B, Co, Ni, As, Cd, Cr, Pb, Hg and Ba are in the A1 quality class. According to RARSWQ; NO3-, o-PO43- and Mn are in between I and II class quality standards. F- and Se are in I.class. TKN, NH3-N and oil-grease are in the III. class. PAH, Pesticide, Zn, B, Co, Ni, As, Cd, Cr, Pb and Ba are in the below the maximum environmental quality system value. CN-, Al, Fe and Cu are in the above the maximum environmental quality system value.

Anahtar Kelimeler
Gumushane Aktutan pond Hazen statistical method (HSM) Bahcecik dam Water resources SCARCITY
WoS Kategorileri
Environmental Sciences Geosciences, Multidisciplinary Water Resources
Sürdürülebilir Kalkınma Amaçları
Künye
Dergi
ENVIRONMENTAL EARTH SCIENCES
Yıl
2023
Cilt
82
Sayı
5
ISSN
1866-6280
eISSN
1866-6299
DOI
10.1007/s12665-023-10799-1
WoS UID
WOS:000935914900002
Yayını aç (DOI)